BJFMR - 26A ANTI-FOUL COATING E790-G75

  • MSDS: BJFMR
  • Manufacturer: SANDSTROM PRODUCTS COMPANY
  • Product Name: 26A ANTI-FOUL COATING E790-G75
  • National Stock Number: 5820-00-135-0639
Product Identification

Product ID:26A ANTI-FOUL COATING E790-G75
MSDS Date:08/16/1990
FSC:5820
NIIN:00-135-0639
Kit Part:Y
MSDS Number: BJFMR

Responsible Party
SANDSTROM PRODUCTS COMPANY
224 SOUTH MAIN STREET
PORT BYRON, IL 61275-9501
US

Emergency Phone: 800-424-9300

Info Phone: 309-523-2121

Cage: 34227

Contractor
SANDSTROM PRODUCTS COMPANY
PORT BYRON, IL 61275 US

Telephone: 309-523-2121

Cage: 34227

Ingredients

PROPYLENE GLYCOL MONOMETHYL ETHER

CAS: 107-98-2

RTECS: UB7700000

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192


METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHYL ALCOHOL (ETHANOL)

CAS: 64-17-5

RTECS: KQ6300000

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM; 9192


METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

OSHA PEL 200 PPM/300 STEL

ACGIH TLV: 200 PPM/300STEL 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


MOLYBDENUM DISULFIDE

CAS: 1317-33-5

OSHA PEL 10 MG/M3

ACGIH TLV: 10 MG/M3


ANTIMONY TRIOXIDE (SARA III)

CAS: 1309-64-4

RTECS: CC5650000

OSHA PEL 0.5 MG/M3 (SB)

ACGIH TLV: 0.5 MG SB/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


BISPHENOL "A" EPOXY RESIN

CAS: 25036-25-3


1,4-DIOXANE (DIETHYLENE DIOXIDE) (SARA III)

CAS: 123-91-1

RTECS: JG8225000

OSHA PEL S, 100 PPM

ACGIH TLV: S, 25 PPM; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


TRIBUTYLTIN OXIDE

CAS: 56-35-9

RTECS: JN8750000

OSHA PEL .1 MG/M3 (SKIN)

ACGIH TLV: .1 MG/M3 (SKIN)


IRRIT TO NOSE,THROAT,RESP TRAC&MUC

RTECS: 9999999ZZ


CNS DEPRESS.BASED ON INGRED 2.EXP TO HIGH CONC OF VAP MAY

RTECS: 9999999ZZ


TOXIC. BASED ON INGRED 8, MAY CAUSE KIDNEY&LIVER DMG.BASED

RTECS: 9999999ZZ


VOMIT MAY RSLT IN SEV LUNG DMG.BASED ON INGRED 1,2,&4,MAY

RTECS: 9999999ZZ


UNUSUAL FIRE&EXPL HAZ(CON'T)THERMAL DECOMP PROD MAY INCLUDE

RTECS: 9999999ZZ


RADIATION MAY CAUSE THE FORMATION

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE:BASED ON INGRED 9,SEV IRRIT,EXP
MAY CAUSE EXTENSIVE CORNEAL INJURY.BASED ON INGRED 1,2,&4,PROD VAP
IRRIT.SKIN:BASED ON INGRED 9,PROD CORROSIVE.BASED ON INGRED 1,8,&9
ABSORPTION MAY RESULT IN SYM O F EXP FOR INHAL & INGEST.BASED ON
INGRED 1,2,3,4&9 PRLNGED/RPTD CONT MAY RESULT IN DEFAT,DRYING OR
DERM.INHAL:SEE INGRED
Explanation of Carcinogenicity:IARC CAR ASSESS: 1.4 DIOXANE - ANIMAL
POSTIVE. NTP CAR ASSESS: METHLENE CHLORIDE - POSTIVE MOUSE, RAT.
Effects of Overexposure:EYE, SKIN, RESP, AND GI IRRITATION AS NOTED IN
HEALTH HAZARDS.BASED ON INGRED 1,2,3,4,&8, CENTRAL NERVOUS SYSTEM
DEPRESSION MAY BE EVIDENCED BY HEADACHE, DIZZINESS, NAUSEA &
SYMPTOMS OF INTOXICATION. IN EXTREME CASES, UNCONSCIOUSNESS AND
DEATH MAY OCCUR.
Medical Cond Aggravated by Exposure:PREEXISTING SKIN, EYE AND RESP
DISORDERS MAY BE AGGRAVATED BY EXP TO THIS PRODUCT. IMPAIRED
CENTRAL NERVOUS SYS FUNCTIONS FROM PREEXISTING DISORDERS MAY BE
AGGRAVATED BY EXP TO THIS PRODUCT.

First Aid

First Aid:EYE: IMMED FLUSH W/ LG AMTS WATER 15+ MIN HOLD LIDS OPEN, GET
MD ATTN.SKIN: REMOVE CONTAM CLTHG & SHOES, FLUSH W/ SOAP & WATER.
DECONTAM CLTHG PRIOR TO REUSE.INHAL: REMOVE TO FRESH AIR. TREAT
SYMP. G IVE O*2 IF DFCLT, ARTF RESP IF NOT BREATHING. GET MD. DO
NOT INDUCE VOMIT. IF IT OCCURS SPONT KEEP VICTIMS HEAD BELOW HIPS
TO PVNT ASPIR. GET MD, POISON CONTROL CENTER, OR TAKE TO EMER
FACILITY.

Fire Fighting

Flash Point Method:PMCC
Flash Point:35.0F,1.7C
Lower Limits:SEE INGRED
Extinguishing Media:USE WATER FOG, FOAM, DRY CHEMICAL, OR CARBON
DIOXIDE.
Fire Fighting Procedures:WARNING, FLAM. CLEAR FIRE AREA OF UNPROT
PERS.DO NOT ENTER CONFINED FIRE SPACE W/O HELMET,FSHLD,BUNKER
COAT,GLOVES,RUB BOOTS, & POS PRESS SCBA.(SEE SUPP DATA).
Unusual Fire/Explosion Hazard:COOL CONTR W/H*20 TO PVNT VAP PRESS
BUILDUP.CONTR AREA EXP TO DIR FLAME SHOULD BE COOLED W/LGE QTY OF
H*20 AS NEEDED TO PVNT CONTR WEAKENING.(SEE INGRED # 14).

Accidental Release

Spill Release Procedures:EVAC AREA. WEAR APPROP RESP & PROT CLTHG. SHUT
OFF LEAK SOURCE IF SAFE. DIKE & CONTAIN. IF VAPOR CLOUD, WATER FOG
TO SUPPRESS; CONTAIN. REMOVE W/ VACUUM TRUCK OR PUMP TO
STORAGE/SALVAGE VESSEL. USE AB SORB ON RESIDUE & DISPOS PROPERLY.
FLUSH W/ WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP LIQUID AND VAPOR AWAY FROM HEAT,
SPARKS AND FLAME.
Other Precautions:KEEP LIQ & VAP FROM HEAT,SPARKS,FLAME.EXTING PILOT
LTS,CIG&OTHER IGNIT SOURCES PRIOR TO USE OR VAP GONE.KEEP CONTR
CLOSED WHEN NOT IN USE.EMPTY CONTR CAN HOLD EXPLO VAP,DO NOT
CUT,DRILL,OR WELD ON OR NEAR THEM.HEAT AND/OR UV (SEE INGRED#15)

Exposure Controls

Respiratory Protection:AVOID PROLONGED OR REPEATED BREATHING OF
VAPOR/DUST. IF EXPOSURE EXCEEDS TLV, USE A NIOSH/MSHA APPROVED
RESPIRATOR TO PREVENT OVEREXPOSURE.
Ventilation:USE VENTILATION AS REQD TO CONTROL OF VAPOR/DUST
CONCENTRATIONS.
Protective Gloves:USE IMPERVIOUS GLOVES
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:EYE WASH FOUNTIANS AND SAFETY SHOWERS.
Work Hygienic Practices:WASH WITH SOAP AND WATER PRIOR TO EATING,
DRINKING, SMOKING, OR USING THE TOILET FACILITIES.
Supplemental Safety and Health
REPORTS HAVE BEEN ASSOC RPTD AND PRLNG OCCUPATIONAL OVEREXPOSURE TO
SOLVENTS W/ PERM BRAIN AND NERVOUS SYSTEM DAMAGE. INTENTIONAL
MISUSE BY DELIBERATELY CONCENTRATING AND INHALING THE CONTENTS MAY
BE HARMFUL OR FATAL.FIRE FIGHTING PROC(CON'T):WEAR NIOSH/MSHA
APPROVED PRESSURE DEMAND SCBA AND FULL PROTECTIVE EQUIP

Chemical Properties

Vapor Pres:SEE INGRED
Vapor Density:>1
Spec Gravity:1.20+/-.2
Evaporation Rate & Reference:<1 (ETHER=1)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:83.78

Stability

Stability Indicator/Materials to Avoid:YES
AVOID OXIDIZERS, STRONG ACIDS, AMINES, ALKANOLAMINES, SODIUM,
POTASSIUM, MAGNESIUM, AND ALDEHYDES.
Stability Condition to Avoid:AVOID HANDLING IN ALUMINUM EQUIPMENT AT
TEMPS OVER 120F. AVOID GROSS WATER CONTAMINATION.
Hazardous Decomposition Products:CHLORINE GAS,HCL,CHLORIN ORGANIC
CMPDS,CO*2,CO AND UNIDENT ORGANIC CMPDS MAY BE FORMED DURING
COMBUSTION.PHOSGENE.

Disposal

Waste Disposal Methods:REFER TO LATEST EPA OR STATE REGULATIONS
REGARDING PROPER DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.